Solution for big industrial plant information Center
Big industrial plant information center is based on the idea of centralized control and corresponding business. According to the requirements of industrial field, the product database is set up in the information center. Then the best core business procedure can be set up by advanced management function on purchase, sales, produce, quality, equipments, storage, logistics and finance. The information center can help different departments to work together and improve the logistics and cash flow. It also can help to distribute company resource more reasonably, strengthen company competitive ability in the market, and improve the service to customers.

Meanwhile, the automatization of equipments operation can be realized by controlling information center. It will improve the work efficiency and management quality.

The information center is like the nerve center of the industrial plant. Lots of servers, information exchangers, monitors and automatic operating equipments are all installed inside the information center.

For example: the framework of automobile enterprise’s information construction system

The size of information center varies from 100 to 500m2. Usually its main computer room r is no more than 200 m2. We recommend Phoenix modularized Precision Control Air Conditioner which is specially made for data room, communication room and computer room. The refrigerant capacity of standard modular varies from 10kW to 80kW. The standard moduls can be assembled flexibly. It can totally fulfill the high requirements of a industrial plant information center.

Method of calculating refrigerant capacity

a) Estimated calculation of refrigerant capacity for a data room: In a middle size information center, the computer room usually is no more than 200m2. If the heat emitting volume of the equipments and building is not confirmed yet, we may calculate the refrigerant capacity according to general volume 300w~500w/m2, and in some computer room with more equipments, it may reach 600 w/m2. For example, the size of data room is 200 m2, so the refrigerant capacity it needs is 80KW. Choosing two sets PDA20/20 with refrigerant capacity 80KW/set,and then its total refrigerant capacity is 85KW which can satisfy the needs. In order to assure the reliability of the equipments, you can add another set PDA20/20 as backup, then 6 moduls in total. You may adjust the moduls according to the final measuring of the heat emitting volume.

b)For monitor room or UPS room, use Precision Control Air Conditioner or normal air conditioner according to the room condition.